Hotel rooms to the measurement details and calculation methods of wooden door
1, first of all, to accurately measure it was high, three times in the order left right amount.
2, want to decorate the door first, and then to decorate the floor here's why: can play crural line installed, first in case of the wall thickness was when need to install the line that play a base, can play crural line, ignore this place for installing a door the door directly to the bottom, the overall look more concise and beautiful. Technological requirements to buckle must be in wooden door, just shut the door after inside and invisible to buckle.
two fundamental principles, the gauge was
1, the standardized record: book form to record the actual measured value, record format shall contain a clear it was high, width, and the wall thickness, as well as the location, door leaf type and attention points ( Such as single wall, the size difference was big, and so on and so forth) 。
2, many attunements values: measuring precision, and more value, the height measurement value was not less than 3 points, the width measurement value was not less than 5.
3, size unification: namely unified as far as possible close to the size, the size of the height, width was accurate to 1 cm, the size of the thickness ( Wall thickness) Uniform size is accurate, such as can not, then minimize the number of two dimensions can not use three sizes.
4, reasonable Suggestions: for it was too wide, Narrow) , too high ( Short) Position, and it was the size difference is too big, the serious influence installation effect, unless the owner must adhere to, deal with the owners put forward Suggestions for improvement.
4, measurement considerations
1, the single wall openings ( Corner wall, t-shaped wall or above beam) Based on 60 mm wide door cover line cases need to increase the wall width is 35 - 40 mm, using 80 mm wide door cover line cases need to thicken the thickness of a brick in the 50 - 60 ㎜, to install the door line.
2, the height of the door should pay attention to the room ground laid thickness of compound floor and wooden floor, floor tile, heating to exclude ( General deduction of 35 ㎜) , on the basis of the floor finish the outseam ㎜ 10.
3, toilet and kitchen is the thickness of the wall was paying special attention to the thickness of the wall brick wall. More general single-sided tile 25 ㎜, two sides 50 ㎜ tile thickening, bricklayer's to ask specific situation.
4, the minimum wall thickness was not less than 80 ㎜. Especially the door head, not enough thick for thickening.
5, the door height to unified around the hotel room, with the lowest it was accurate. Swallow the height error more than 10 ㎜ demands, looks neat and beautiful.
6, it was too narrow, recommend 60 ㎜ door cover line.
5, wooden door measurement conditions:
we need to put the ground leveling before measuring ruler, confirm the material thickness. Because I have to get the house we can feel the ground not level off, if the leveling will be sent out a lot, and even a few centimeters! Although several centimeters, if feet measurement error will be a lot at this moment, even make a door to install! Floor or tile measuring ruler again don't have to shop, but didn't confirm thickness told gauge workers can!
about the location of the need to stick wall brick, because now the wooden door installation has gone through a traditional carpentry era, but use styrofoam filled in. This lets the door and wall connection firmer. So the wall thickness is also very strict. Because just bought house toilet and kitchen wall brick by having to metope leveling, so it is to produce a certain thickness. We must put the wall brick shop is complete, the wooden door measuring scale, more accurate!
6, the size of the late finishing
1, according to the measurement of the fundamental principle of the measurement result, unification as much as possible.
2, lock to note: if you want to manufacturer the lock hole, submitted to the feet, shall indicate the lock of the door to.
3, for the door handle distribution unit, minus the thickness of the handle, and leave room to adjust.
4, after finishing the size was highly minus 10 mm, width of minus 15 mm, the thickness of remained unchanged.
5, finishing the content such as the size of the special requirements and specifications, according to the size of the room alone, the production of door frame size order as required.
6, single wall minus 10 - door width It is good to 15 mm.